declared thermal conductivity λ: 0.031 W/(m*K), fire classification E in accordance with EN 13501-1
Colour shade
grey
Format
100 x 50 cm, edges: straight 5 - 20 cm, edges: stepped groove 21 - 30 cm
Notes
design thermal conductivity λ: 0.032 W/(m*K) in the plinth area outside the soil design thermal conductivity λ: 0.036 W/(m*K) in the soil (perimeter) in accordance with the quality guideline of the Industrieverband Hartschaum e.V. (IVH) and Verband für Dämmsysteme, Putz und Mörtel e.V. (VDPM)
exterior, as an insulation board in splash zone (plinth) and soil (perimeter), fixing by bonding, not permitted in the capillary fringe of the ground water (generally approx. 30 cm above the WT) and in the area of pressing water
Downloads